A fair quote does three things: its price sits in the usual range for the job, it names the exact equipment, and it puts the essentials in writing. Enter the details from your quote above to check all three, then send it to us if you want a second opinion.
What the checker compares your price with
The usual range comes from the same budgeting bands, checked against UK prices in November 2026, as our installation cost calculator: about £1,500 to £3,000 including VAT for one room on a single split in most of the UK, and about £1,800 to £3,500 in London, with allowances for extra rooms, flats and the extra work you tick. The cost methodology explains how the bands were built. Ceiling cassettes and ducted systems are priced by the ceiling, so the checker reviews the scope for those and leaves the price to a survey.
How to read the price verdict
- Below the usual range. Check nothing has been left out. Electrics, the drain, making good and VAT are the usual gaps. Confirm the model codes are the range you expect.
- Within the usual range. The price is plausible. Decide on equipment, scope and the installer's evidence, not on the last £100.
- Above the usual range. Ask what drives it. Long pipe runs, access equipment, electrical upgrades and premium equipment can all justify more. If none apply, get a comparison quote.
The twelve things a complete quote states
| The quote states | Why it matters | If it is missing, ask |
|---|---|---|
| Exact indoor and outdoor model codes | The range decides efficiency, noise and a large part of the price. "Daikin 2.5 kW" could be a Sensira or a Perfera. | Which exact indoor and outdoor model codes are you quoting? |
| Capacity in kW for each room | An undersized unit runs flat out; an oversized one switches on and off and controls humidity badly. | What kW is each indoor unit, and how did you size each room? |
| Where the outdoor unit goes | The position sets the noise at your neighbour's window, the planning position and the pipe length. | Where exactly will the outdoor unit sit, and on what fixing? |
| Pipe route and length | Long or concealed runs add labour and can need extra refrigerant. | What route do the pipes take, how long is the run, and is trunking included? |
| Condensate drain or pump | A poor drain fall or a failed pump is behind most water leaks. | Does the condensate drain by gravity or a pump, and where does it discharge? |
| Electrical supply and isolators | A new circuit or consumer-unit work is a common extra that some quotes leave out. | Is the power supply, the isolator and any new circuit included in this price? |
| Core hole sealing and making good | Without it you are left with exposed holes, trunking ends and unpainted patches. | Is sealing the core hole and making good around the units included? |
| Commissioning and handover records | A pressure test, evacuation and a written commissioning record protect the warranty. | Will I get a commissioning record and the user guide at handover? |
| Warranty length and who registers it | Longer manufacturer warranties usually depend on registration and annual servicing. | How long is the warranty, who registers it, and what servicing does it require? |
| F-gas company certificate number | A business must hold an F-gas company certificate to install a split system. You can check the number on the certification body's register. | What is your F-gas company certificate number, and which body issued it? |
| Whether VAT is included, and at what rate | Two quotes can look hundreds of pounds apart only because one leaves VAT off. | Does this total include VAT, and at what rate? |
| Deposit and payment stages | Clear stages protect you if the job is delayed or changes. | What deposit do you need, and when is the balance due? |
Which range is on your quote?
The model code tells you which range you are paying for. These are the published figures at 2.5 kW for the ranges most UK quotes name, checked 21 November 2026. SEER is the seasonal cooling efficiency and SCOP the seasonal heating efficiency: higher is cheaper to run.
| Range | Tier | SEER | SCOP | Quietest setting |
|---|---|---|---|---|
| Daikin Sensira Codes start FTXF | Entry | 6.5 | 4.2 | Not on the sheet we used |
| Daikin Comfora Codes start FTXP | Mid-range | 7.2 | 4.61 | Not on the sheet we used |
| Daikin Perfera Codes start FTXM | Premium | 9.47 | 5.2 | Not on the sheet we used |
| Daikin Stylish Codes start FTXA | Designer | 8.74 | 5.15 | Not on the sheet we used |
| Daikin Emura Codes start FTXJ | Designer | 8.74 | 5.15 | 19 dB(A) |
| Daikin Ururu Sarara Codes start FTXZ | Flagship | 9.54 | 5.9 | Not on the sheet we used |
| Mitsubishi Electric MSZ-HR Codes start MSZ-HR | Entry | 6.2 | 4.3 | 21 dB(A) |
| Mitsubishi Electric MSZ-AY Codes start MSZ-AY | Premium | 8.7 | 4.8 | 18 dB(A) |
| Mitsubishi Electric MSZ-EF Zen Codes start MSZ-EF | Designer | 9.1 | 4.7 | Not on the sheet we used |
| Mitsubishi Electric MSZ-LN Codes start MSZ-LN | Flagship | 10.5 | 5.2 | Not on the sheet we used |
| Panasonic Etherea Codes start CS-Z | Premium | 9.5 | 5.2 | Not on the sheet we used |
| Panasonic TZ Codes start CS-TZ | Entry | Not verified | Not verified | Not on the sheet we used |
| Toshiba Seiya Codes start RAS-B..E2KVG | Entry | Not verified | Not verified | Not on the sheet we used |
| Toshiba Shorai Edge | Premium | 8.6 | 5.1 | 19 dB(A) |
| Toshiba Haori Codes start RAS-B..N4KVRG | Designer | 8.5 | 5.1 | Not on the sheet we used |
| Samsung WindFree Comfort Codes start AR..TXFCAWK | Mid-range | 6.7 | 4.0 | 19 dB(A) |
| Samsung WindFree Elite | Premium | 8.8 | 5.1 | Not on the sheet we used |
| LG Artcool Mirror Codes start AC..BK | Designer | 7.0 | 4.0 | Not on the sheet we used |
| Fujitsu KMCC Codes start ASYG..KMCC | Mid-range | 7.4 | 4.1 | Not on the sheet we used |
| Fujitsu KMCG Codes start ASEH..KMCG | Premium | 8.4 | 4.6 | Not on the sheet we used |
| Hitachi airHome 400 | Mid-range | 7.5 | 4.6 | Not on the sheet we used |
| Fujitsu KLTB Codes start ASEH..KLTB | Entry | 6.8 | 4.1 | Not on the sheet we used |
| Fujitsu KNCA Codes start ASEH..KNCA | Mid-range | 7.4 | 4.4 | Not on the sheet we used |
| Fujitsu KJCA Codes start ASEH..KJCA | Flagship | 9.2 | 5.1 | Not on the sheet we used |
| Hitachi airHome 600 Codes start RAK-VJ..PHAE | Premium | 8.5 | 4.9 | Not on the sheet we used |
| Bosch Climate 3000i Codes start CL3000i | Mid-range | 7.4 | 4.1 | Not on the sheet we used |
An entry range is fine for a room cooled a few weeks a year. For a bedroom or living room used daily, a premium range costs less to run and is usually quieter. A designer range costs more for its casing, not for more cooling.
When to get another quote
- The quote does not name the model codes and the installer will not add them.
- The price is above the usual range and nothing on site explains it.
- Fewer than eight of the twelve essentials are in writing.
- The business cannot give an F-gas company certificate number.
Use the form at the bottom of this page to ask local installers for comparison quotes on the same scope, or read how to compare installation quotes and deposits and stage payments.
Sources
- GOV.UK: certification for companies working on equipment containing F-gas
- GOV.UK: VAT on energy-saving materials and heating equipment (Notice 708/6)
- Citizens Advice: getting home improvements done
- Daikin Sensira: published figures
- Daikin Comfora: published figures
- Daikin Perfera: published figures
- Daikin Stylish: published figures
- Daikin Emura: published figures
- Daikin Ururu Sarara: published figures
- Mitsubishi Electric MSZ-HR: published figures
- Mitsubishi Electric MSZ-AY: published figures
- Mitsubishi Electric MSZ-EF Zen: published figures
- Mitsubishi Electric MSZ-LN: published figures
- Panasonic Etherea: published figures
- Panasonic TZ: published figures
- Toshiba Shorai Edge: published figures
- Toshiba Haori: published figures
- Samsung WindFree Comfort: published figures
- Samsung WindFree Elite: published figures
- LG Artcool Mirror: published figures
- Fujitsu KMCC: published figures
- Fujitsu KMCG: published figures
- Hitachi airHome 400: published figures
- Fujitsu KLTB: published figures
- Fujitsu KNCA: published figures
- Fujitsu KJCA: published figures
- Hitachi airHome 600: published figures
- Bosch Climate 3000i: published figures
Frequently asked questions
How do I know if an air conditioning quote is fair?
Check three things. The price should sit in the usual range for the number of rooms, the system type and your region. The quote should name the exact model codes, so you know which range you are paying for. And it should state the twelve essentials in writing, from the outdoor unit position to the F-gas certificate number. The checker does all three.
Why are my quotes so far apart?
Usually because they are not for the same job. One names a premium range and includes a new electrical circuit; another names nothing and leaves out electrics, the drain and VAT. Make each installer price the same rooms, the same outdoor position and the same scope, then compare.
Is the cheapest quote a bad sign?
Not by itself. It is a bad sign when the quote does not name the model codes, leaves out electrics or making good, or cannot give an F-gas company certificate number. A low price for a complete, named scope is simply a good price.
Should the quote include VAT?
It should say clearly whether it does and at what rate. Many jobs are standard-rated at 20%. HMRC's Notice 708/6 allows a zero rate, until 31 March 2027, on installing qualifying air source heat pumps in homes, and the VAT-registered installer decides whether a job qualifies. Compare quotes on the total you would pay.
What happens if I send you my quote?
We read it and reply by email with whether the price is in the usual range for the work described, what is missing and the questions to ask before you sign. We only pass your details to installers if you tick the box asking for comparison quotes.
Does the installer have to be F-gas certified?
Yes. Split systems contain refrigerant, and the business installing one must hold an F-gas company certificate, with individually qualified engineers doing the work. Ask for the certificate number and check it with the body that issued it.
More free tools
- Installation cost calculator: Budget a home installation by rooms, region, system type and site extras.
- Running cost calculator: Estimate electricity cost from your tariff, the unit's input and hours of use.
- Heating cost calculator: Compare heating a room with air conditioning, an electric heater and a gas boiler.
- Sizing calculator: Estimate the kW a room needs from its size, type and heat gains.
- BTU calculator and converter: Work out the BTU a room needs and convert BTU to kW.
- Planning permission checker: Answer nine questions to see which consents your installation is likely to need, in any UK nation.
- Heat pump grant checker: See whether the £2,500 Boiler Upgrade Scheme grant for an air-to-air heat pump is likely to apply to your home.
- Fault code lookup: Look up error codes for Daikin, Mitsubishi Electric, Panasonic, LG, Samsung, Fujitsu, Mitsubishi Heavy Industries, Haier and Gree.
- Commercial cost calculator: Budget an office, shop or hospitality installation by zones and site factors.
- Server room cost calculator: Budget IT cooling from heat load, redundancy and site factors.