A reversible unit on a house in England or Wales can often go in without a planning application if it meets every permitted development condition. Scotland's right covers heating and hot water only, so air conditioning there usually needs an application, and Northern Ireland has its own position rules. Planning is also only one consent: leases and landlords can still say no.
The rules the checker applies
| Rule | England | Wales | Scotland | Northern Ireland |
|---|---|---|---|---|
| Reversible air conditioning covered? | Yes, if not used solely for cooling (since 29 May 2025) | Yes, heating or heating and cooling (since 1 June 2026) | No: domestic heating or hot water only | Must provide heat |
| Units per house | Two if detached, otherwise one | Two if detached, otherwise one | One | One |
| Flats | One per block, outdoor unit up to 0.6 m³ | Not covered | Not covered | Not covered |
| Outdoor unit size | Up to 1.5 m³ on a house | Up to 1.5 m³ | No more than 1 m protrusion from the wall or roof | Up to 3 m high |
| Roofs | Not on a pitched roof; flat roof only 1 m+ from the edge | Not on a pitched roof; flat roof only 1 m+ from the edge | Within the 1 m protrusion limit | Not on any roof |
| Walls facing a road | Not above ground-floor level | Not above ground-floor level | Not in front of a road-facing elevation | Not in front of a road-facing elevation |
| Conservation areas and World Heritage Sites | Not on a wall or roof fronting a road, or nearer the road than the house | Same as England (conservation areas) | Conservation area: rear wall at ground floor only. World Heritage Site: not covered | No part facing and visible from a road |
| Listed buildings | Not covered | Not covered | Not covered | Only after listed building consent |
| Distance from neighbour | Noise assessment (MCS 020) instead of a distance rule | Noise assessment (MCS 020(a)) | MCS planning standards | Not within 1 m of a neighbour's boundary |
Conditions that still apply when no application is needed
Permitted development is conditional. In England and Wales the unit must meet the MCS 020 noise assessment at the nearest neighbouring window, and it must be sited to minimise its effect on the building's appearance and the area. A unit that fails the noise assessment is not permitted development even if it is small and at the back. Article 4 directions and planning conditions on newer estates can remove the rights altogether. Commercial premises are outside these domestic rights, so ask the council.
Consents that are not planning
- Leasehold: the lease and the freeholder's consent, usually a licence for alterations.
- Renting: the landlord's written permission.
- Shared or party walls: agreement with the neighbour may be needed.
- Noise: a statutory nuisance complaint can follow even where planning was not required.
Getting certainty
If the answer matters, for example before a sale, apply for a lawful development certificate. It is the council's formal confirmation that the work is lawful. An informal email from a planning officer is useful but not binding.
Read the detail
- Do you need planning permission for air conditioning?
- Air conditioning planning permission in England
- Flats, leaseholders and freeholder consent
- Listed buildings and conservation areas
- Outdoor unit noise
Sources
- UK legislation: Class G, air source heat pumps on domestic premises
- UK legislation: 2025 amendment to Class G
- Welsh Government: planning permission for domestic heat pumps (updated 1 June 2026)
- UK legislation: Scotland Class 6H, air source heat pumps
- UK legislation: Northern Ireland Class G, air source heat pumps
- Scottish Government: permitted development rights consultation (closed 27 October 2025)
- Planning Portal: planning permission for air source heat pumps
- Planning Portal: do I need planning permission to add air conditioning to my home?
Frequently asked questions
Do I need planning permission for air conditioning in the UK?
It depends on the nation. In England and Wales a reversible unit that heats as well as cools can be permitted development on a house if it meets every condition on number, size, position and noise. In Scotland the permitted development right for heat pumps covers heating and hot water only, so air conditioning usually needs an application. Northern Ireland allows one heat pump per house that provides heat, with its own position rules.
Why does it matter whether the unit can heat?
The permitted development rights for outdoor units cover air source heat pumps. England (since 29 May 2025) and Wales (since 1 June 2026) allow a unit that heats and cools, but not one used solely for cooling. Northern Ireland requires the unit to provide heat. Scotland's right is limited to domestic heating or hot water.
Do flats need planning permission for air conditioning?
In England, since 29 May 2025, permitted development can cover one heat pump on or within the curtilage of a whole block of flats, with an outdoor unit of no more than 0.6 cubic metres. If any flat in the block already has one, a second needs an application. Wales, Scotland and Northern Ireland do not extend the right to flats, so expect to apply. Every flat also needs the freeholder's or management company's consent.
How many outdoor units can a house have without planning permission?
In England and Wales, up to two on a detached house and one on a semi-detached or terraced house. In Northern Ireland, one per property. In Scotland, one, and only for heating or hot water.
Is this checker legal advice?
No. It applies the main permitted development rules for each UK nation to your answers and tells you what to check. Only your local planning authority can confirm the position for your address, and a lawful development certificate (a certificate of lawfulness in Scotland and Northern Ireland) is the formal way to get certainty.
More free tools
- Installation cost calculator: Budget a home installation by rooms, region, system type and site extras.
- Quote checker: Check a quote you have been given: price, equipment and what it leaves out.
- Running cost calculator: Estimate electricity cost from your tariff, the unit's input and hours of use.
- Heating cost calculator: Compare heating a room with air conditioning, an electric heater and a gas boiler.
- Sizing calculator: Estimate the kW a room needs from its size, type and heat gains.
- BTU calculator and converter: Work out the BTU a room needs and convert BTU to kW.
- Heat pump grant checker: See whether the £2,500 Boiler Upgrade Scheme grant for an air-to-air heat pump is likely to apply to your home.
- Fault code lookup: Look up error codes for Daikin, Mitsubishi Electric, Panasonic, LG, Samsung, Fujitsu, Mitsubishi Heavy Industries, Haier and Gree.
- Commercial cost calculator: Budget an office, shop or hospitality installation by zones and site factors.
- Server room cost calculator: Budget IT cooling from heat load, redundancy and site factors.