When Mitsubishi Electric moves past the AY sizes, the large wall units are MSZ-AP. The 6.1 kW cooling model pairs with MUZ-AP60VG2. The 7.1 kW pairs with MUZ-AP71VK2. Both are published as single phase. Quiet cooling starts at 30 dB(A), not the 18 dB(A) of a small AY. SEER is 7.40 and 7.20. They are the right shape for one big room. They are the wrong shape for a light sleeper who liked the AY brochure.

The point where AY stops
AY covers the familiar bedroom and living-room sizes, up to 5.0 kW on the current sheet, with the tiny 1.5 kW as multi-split only. AP is the chassis for 6.1 and 7.1 kW nominal cooling. The indoor unit grows to 1100 mm wide, 325 mm high and 257 mm deep, 16 kg on the 6.1 and 17 kg on the 7.1. That is a piece of furniture. Find a wall that can take the width and the fixings.
People ask for 'the quiet Mitsubishi' and are handed a 7 kW because the room is large. The quiet step on these two is 30 dB(A) in cooling, then 37, 41, 45 and up to 48 or 49 at the top. Fine for a kitchen diner. A poor surprise in a nursery. If the room is both large and slept in, look at two smaller heads before you accept one loud one.
Daikin's 7.1 kW guide is the natural cross-shop. This page keeps the Mitsubishi codes straight so the quote cannot wobble between AY and AP.
The two large sizes
Heating and cooling classes are printed heating first on Mitsubishi's sheet. Both outdoors are single phase, 220-240 V. Nominal cooling input is about 1.59 kW on the 60 and 2.01 kW on the 71. That is what the electrician feels.
| AP60, 6.1 kW | AP71, 7.1 kW | |
|---|---|---|
| Cool / heat nominal | 6.1 / 6.8 kW | 7.1 / 8.1 kW |
| SEER / SCOP | 7.40 / 4.60 | 7.20 / 4.40 |
| Class, heat / cool | A++ / A++ | A+ / A++ |
| Quietest cooling | 30 dB(A) | 30 dB(A) |
| Cooling input, nominal | 1.59 kW | 2.01 kW |
| Outdoor cool sound | 56 dB(A) | 55 dB(A) |
| Indoor size | 1100 x 325 x 257 mm | 1100 x 325 x 257 mm |
Single phase, and still a serious circuit
The three-phase guide on this site is for quotes that really want a supply upgrade. These AP outdoors are published as single phase, so a 7.1 kW wall unit is not an automatic call to the network operator. It is a call to the electrician, because 2 kW of cooling input plus a cooker and an EV charger can still crowd a cut-out. The single-phase limit guide is the companion that refuses a fake universal amp number.
Outdoor units are physically bigger than a bedroom condenser. The 71 is listed at 840 mm wide, 330 mm deep and 880 mm high. Weight on the sheet is 53 kg. The bracket, the wall and the lift are part of the price. A first-floor gable is a different job from a ground-floor alley.
Pipe sizes step up: the gas pipe on these two is 1/2 inch rather than 3/8. Anyone reusing old 3/8 lines from a smaller unit needs the flushing and reuse guides, and a straight answer that the old pipe may be the wrong bore.
One big head, or two smaller ones
A hall, a school-room-sized kitchen, or a village hall committee room can be a single AP. An open-plan space with a seating end and a cooking end often behaves better with two indoors on a multi-split, so you can turn the cooking head down. AP is one-room capacity. Zoning wants a second indoor unit.
Sound outside at 55 or 56 dB(A) in cooling is the planning conversation. Bedroom AYs hide in the high 40s. This does not. Measure to the neighbour's window before the crane day.
Ask for UK cooling and UK heating rows as well as nominal. Mitsubishi prints both. Nominal is a test point. The UK column is the one that feels like your weather. Then compare with a Daikin 7.1 on the same wall if both companies can attend.
Frequently asked questions
Is MSZ-AP the same as MSZ-AY?
AY is the smaller range, with lower sound and higher SEER on the bedroom sizes. AP60 and AP71 are the large single-phase wall units. The fascia and the decibels both change.
Do I need three phase for 7.1 kW?
Mitsubishi lists MUZ-AP71VK2 as single phase. Confirm the code, then let an electrician see the rest of the board. Three phase is a supply question, not an automatic feature of this model.
Will it be quiet at night?
The lowest published cooling step is 30 dB(A). That can be fine in a living room and busy beside a pillow. Use a smaller class if sleep is the product you are buying.
Can the old small-bore pipes be reused?
These sizes specify 12.7 mm gas pipe. A line that was 9.52 mm for a bedroom unit is a different design. The installer should say so before the old copper is written into the quote.
Core buying guides
Start with these high-intent guides, then dig into the rest of the library.
Related guides
More homes guides
Sources and further reading
How this guide was prepared
This guide was written by the Local AC Installers Editorial Team. We compare official guidance, legislation and established consumer information, separate general information from project-specific advice, and show publication dates and sources. We do not accept installer accreditation claims at face value.