System design

Does Air Conditioning Bring In Fresh Air? Fresh-Air Cooling and Ventilation Systems Compared

Which UK home systems bring in outside air and which only recirculate: wall splits, single and dual hose portables, fresh-air spigots, Ururu Sarara, MVHR, PIV and extract fans, with Approved Document F rates and makers' power figures.

  • 8 min read
  • Updated 29 November 2026
  • 18 named sources

By Local AC Installers Editorial Team · Published · Updated

Most home air conditioning does not bring in fresh air: a wall split or a portable cools the air already in the room and sends it back. In a UK home, a fresh air cooling system is usually two things working together, a split for the cooling and a ventilation system (MVHR, positive input ventilation or extract fans with trickle vents) for the outdoor air. The one domestic wall split we found with a designed fresh-air path is Daikin's Ururu Sarara, which Daikin rates at 30 m³/h of outdoor air. That is about 8.3 litres a second, under half the 19 l/s that Approved Document F sets for a whole one-bedroom home. The table below shows which systems bring in outside air, how, and what each example costs to run on its maker's own power figure at the Ofgem cap of 26.32p per kWh.

Wall mounted split in a UK bedroom with the window closed

Which systems bring in outside air

Each row names one example model so the power figure can be checked against the maker's own document. Running costs are our arithmetic at the Ofgem price cap unit rate for 1 October to 31 December 2026 (26.32p per kWh, GB average, direct debit). Ventilation runs all day, so its cost is worked out for a year of continuous running; cooling is worked out from the maker's seasonal figure or per hour. These are single examples from makers' documents, not a survey of every model, and we have not tested any of these products.

A single hose portable needs a word of its own. GE Appliances, which makes them, says a single hose unit pulls air from the room and blows warmed air and moisture outside, so the same amount of air is sucked back in through cracks under doors and around windows. That is outdoor air, but it arrives unfiltered and warm on a hot day, so it works against the cooling rather than being ventilation you would choose. A dual hose unit takes the air for its hot side from outdoors through a second hose, and GE says it should not create that negative pressure. The room air on its cool side is still recirculated.

The ducted or cassette row depends on the building work. Mitsubishi Electric's installation manual for its PLFY ceiling cassette shows a cut-out in the casing for a fresh-air intake duct, and says a duct fan used to bring outside air in must be linked to the air conditioner and must not run on its own, because that can cause condensation. The outdoor air comes from that separate, site-supplied duct and fan, so ask the installer to name both on the quote.

Home cooling and ventilation systems: outdoor air, makers' power figures and running cost (checked 29 November 2026)
System, with the example we usedBrings in outdoor air?How it handles airMaker's power figureRunning cost at 26.32p per kWh
Wall split (Daikin Perfera FTXM25A)NoRecirculates room air; the pipes carry refrigerant, not air.92 kWh a year seasonal cooling (EN 14825), DaikinAbout £24 a year for cooling
Portable, single hose (electriQ EcoPlus 12000)Not by designBlows room air out; warm air leaks back in through gaps.1,129 W cooling input, electriQAbout 30p an hour
Portable, dual hoseOnly for its hot sideOutdoor air cools its hot side only; room air recirculates.No UK maker figure foundNot worked out
Ducted or cassette unit with a fresh-air spigot (Mitsubishi Electric PLFY cassette)Yes, with a duct and fanA separate duct and fan feed outdoor air into the unit.Depends on the duct fan chosenDepends on the duct fan chosen
Split with a fresh-air function (Daikin Ururu Sarara FTXZ25N)YesTakes in outdoor air while it heats, cools and humidifies.30 m³/h ventilation, 92 kWh a year seasonal cooling (EN 14825), DaikinAbout £24 a year for cooling
MVHR (Vent-Axia Sentinel Econiq S)Yes, all the timeSupplies filtered outdoor air, extracts stale air, recovers the heat.SFP 0.46 W per l/s, 92% thermal efficiency (SAP PCDB, kitchen plus two wet rooms), Vent-AxiaAbout £33 a year at 31 l/s, our arithmetic
PIV (Nuaire Drimaster-Eco HC)Yes, all the timeLoft unit pushes filtered air in; stale air leaves through gaps.1.6 W minimum to 17 W maximum, NuaireAbout £3.70 to £39 a year
dMEV or extract fan (Vent-Axia Lo-Carbon Revive 7)IndirectlyExtracts from wet rooms; outdoor air enters through trickle vents.1.4 W on 6 l/s trickle, 26 W on 60 l/s kitchen boost, Vent-AxiaAbout £3.20 a year per fan on trickle; under 1p an hour on full boost

How much fresh air a home needs: Approved Document F

Approved Document F Volume 1 is the government's guidance on ventilation in new homes and building work in England. The figures below are the same in the 2021 edition and the 2026 edition on GOV.UK. They are design minimums for meeting the Building Regulations, not a test of an existing house, but they show the scale of air a home is expected to exchange.

For the whole home, the supply rate should be at least 0.3 litres a second for each square metre of internal floor area, counting every floor, and at least the rate for the number of bedrooms in the table, whichever is higher. A home with only one habitable room uses 13 l/s, and each bedroom above five adds 6 l/s. Each habitable room also needs purge ventilation, such as an opening window, able to extract at least four air changes an hour.

The last column puts Ururu Sarara's figure beside those rates. Daikin's 30 m³/h is about 8.3 l/s, our conversion. That is a useful trickle of outdoor air for the room the unit is in, but it is not whole-home ventilation, which is why Daikin's own range and this page treat ventilation as a separate job in most homes.

Minimum whole-dwelling ventilation rates, Approved Document F Volume 1, Table 1.3 (checked 29 November 2026)
BedroomsMinimum whole-dwelling rate (l/s)Ururu Sarara's 8.3 l/s as a share of it
119About 44%
225About 33%
331About 27%
437About 23%
543About 19%

Extract rates for kitchens and bathrooms

Extract ventilation in Approved Document F can run when needed (intermittent) or all the time at a low rate with a boost (continuous, which is what dMEV and MVHR do). For a continuous system, the sum of all the continuous rates in the home should be at least the whole-dwelling rate in the table above.

Approved Document F also says a recirculating cooker hood on its own is not a means of ventilation that meets Part F. The same logic applies to a wall split: filtering and cooling room air is not the same as changing it.

Minimum extract rates, Approved Document F Volume 1, Tables 1.1 and 1.2 (checked 29 November 2026)
RoomIntermittent extract (l/s)Continuous extract, high rate (l/s)
Kitchen, cooker hood extracting outside3013
Kitchen, no hood or a recirculating hood6013
Utility room308
Bathroom158
Toilet66

What a wall split does with the air

The indoor unit moves room air across a cold coil and hands it back. That is recirculation. It is why a split can make a closed room comfortable so quickly, and why a smell from the kitchen lingers in a shut bedroom however long the split runs.

Energy Saving Trust describes these machines as air-to-air heat pumps when they heat. The refrigerant carries heat between the indoor coil and the outdoor unit. The air in the room and the air in the garden meet the coils, but they do not swap places. The whoosh from the outdoor unit is its fan rejecting heat, or collecting it in winter.

On a humid July afternoon the indoor coil runs colder than the room, so water condenses on it and leaves through the condensate pipe. The air that comes back is cooler and a bit drier, which can make a shut room feel fresher, but CO2 from two people working in a small office still climbs. Dry mode leans on that moisture removal and heating mode warms the same air; neither is a supply of outdoor air. The filters on the indoor unit protect the coil and catch some dust. Streamer, nanoe X and similar features still sit inside a recirculating box unless the maker shows a fresh-air path.

When Ururu Sarara makes sense

Daikin's UK page for the FTXZ-N indoor and RXZ-N outdoor pair describes humidification, dehumidification, ventilation, air purification, heating and cooling in one system. Daikin's FTXZ-N catalogue gives the ventilation capacity as 30 m³/h and says the system can fill a room of more than 26 m² with fresh air in under two hours. The UK page itself does not print the airflow figure. The 2.5 kW Ururu and the 2.5 kW Perfera are both rated at 92 kWh a year for seasonal cooling; Daikin does not publish a separate power figure for the ventilation fan.

That makes it worth a look for a study or bedroom that overheats and feels shut in, or where winter air is uncomfortably dry. It is a poor default for someone who only wants July cooling in a house that already has trickle vents and a working extract fan. The Ururu Sarara guide on this site covers the product; this page stays with the fresh-air question.

Offices and shops with a large system are a different design. They often pair fan coils or VRF with a separate air handling unit that brings outdoor air in, sometimes with heat recovery. If a quote for a commercial building is silent on fresh air, ask which system is doing the ventilation. GOV.UK's inspection guidance for systems over 12 kW covers the cooling plant, a reminder that comfort cooling and ventilation are named separately in proper building work.

Running cooling and ventilation together

Use the split with the room closed when you want the temperature, and the ventilation you have when you want outdoor air. MVHR, PIV and dMEV run all day at low power, so they can keep going while the split cools; opening a window wide on a hot afternoon pours the cooling into the street. Many MVHR units also have a summer bypass, covered in the MVHR summer bypass guide, which stops them warming incoming air in summer.

On a survey, say how you ventilate today. A loft room with one skylight and a shut door is a different brief from a kitchen diner with a hood that extracts outside. The installer sizes the cooling for the heat; the ventilation keeps the air changing.

Fitted splits still need an F-gas certified company for the refrigerant circuit, and the outdoor unit in England sits under Planning Portal rules for many householder jobs. Fresh air changes the brief you give, not those rules.

Frequently asked questions

What is a fresh air cooling system?

For a UK home it usually means cooling plus ventilation: a split or ducted air conditioner for the temperature and MVHR, PIV or extract fans for outdoor air. Daikin's Ururu Sarara is a wall split with its own fresh-air function, rated by Daikin at 30 m³/h, about 8.3 l/s.

Does a portable air conditioner bring in fresh air?

Not by design. A single hose unit blows room air outside, and GE Appliances says the same amount is sucked back in through gaps under doors and around windows. A dual hose unit uses outdoor air only to cool its hot side; the air in the room is recirculated.

Will leaving the split on all day freshen a home office?

It will hold the temperature and, in cooling, take some moisture out. Two people in a shut room still need outdoor air from a window, trickle vents or a ventilation system, because the split is recycling what is already there.

Does dry mode count as fresh air?

No. Dry mode is a moisture setting on a recirculating unit. The air is the same air, a little drier.

How much does ventilation cost to run next to air conditioning?

On makers' figures at 26.32p per kWh: about £3.20 a year for a Vent-Axia Revive 7 extract fan on trickle, £3.70 to £39 a year for a Nuaire Drimaster-Eco PIV unit, and about £33 a year for a Vent-Axia Econiq S MVHR unit at 31 l/s with a kitchen and two wet rooms (our arithmetic). A 2.5 kW Daikin split uses about £24 a year for cooling on Daikin's seasonal figure.

Can I just open the window a crack while it runs?

You can. On a hot day the unit then cools the street as well as the room. A short airing with the compressor paused, then a closed room, uses the machine for what it is good at.

Core buying guides

Start with these high-intent guides, then dig into the rest of the library.

Related guides

More technology guides

Sources and further reading

How this guide was prepared

This guide was written by the Local AC Installers Editorial Team. We compare official guidance, legislation and established consumer information, separate general information from project-specific advice, and show publication dates and sources. We do not accept installer accreditation claims at face value.

Read our full editorial policy.

Get a quote

Get AC installation quotes

Start with the installation postcode and service. Add optional detail only if you have it.

Free, no obligationSubmit the form at no cost. You decide whether to accept any quote.

Local introductionsWe pass your enquiry to installers covering the postcode. Reply speed and volume both vary.

No lead sellingDetails go only to relevant installers for quote contact. See the privacy notice.

Ask each company for F-Gas registration and insurance. We introduce local installers.

Add more project detail (optional)

You choose whether to accept any quote. Read our installer checks and privacy notice.