WindFree Elite is Samsung's small, very quiet wall split. The UK product sheet lists 2.5 and 3.5 kW only, both A+++ for cooling and heating, with a silent indoor figure of 16 dB(A). The 2.5 kW posts SEER 8.8 and SCOP 5.1. The pipe limit is 15 metres with 8 metres of height, which is the fact that removes it from long terraces. The wider WindFree guide explains the micro-hole idea. The AY comparison covers WindFree as a family. This page is the Elite sheet.
What the silent number is measuring
Samsung prints indoor sound pressure as 38/16 dB(A) on the 2.5 kW (AR09TXCAAWKNEU indoors) and 40/16 on the 3.5 kW (AR12). High fan is the first number. Silent is 16. WindFree mode pushes air through the field of small holes so the draught on your arm eases off. It is still room air, still a split, still a fan when the room needs a proper push.
Cooling power input at the nominal point is about 0.54 kW on the 2.5 and about 0.89 kW on the 3.5, with maxima on the sheet around 0.93 and 1.45 kW. Those are the battery and the breaker numbers. Cooling capacity is the comfort number. Keep them separate.
Outdoor sound is 45 dB(A) on the 2.5 kW sheet and 46 on the 3.5. The 16 is indoors. Neighbours get the mid-40s. Siting and Planning Portal rules are the outdoor half of an otherwise gentle product.
The sheet, side by side
Both sizes share the indoor carcass: 889 mm wide, 299 mm high, 215 mm deep, 10.6 kg. Refrigerant charge is 0.97 kg of R32. Pre-charge covers 5 metres. Maximum length 15 metres, maximum height 8 metres, additional charge 15 g per metre. That last cluster is where Elite becomes the wrong tool.
| 2.5 kW | 3.5 kW | |
|---|---|---|
| Cooling | 2.50 kW (0.90-3.60) | 3.50 kW (0.90-4.80) |
| Heating | 3.2 kW (0.8-7.10) | 4.00 kW (0.80-7.30) |
| SEER / SCOP | 8.8 / 5.1 | 8.5 / 5.1 |
| Class | A+++ / A+++ | A+++ / A+++ |
| Indoor high / silent | 38 / 16 dB(A) | 40 / 16 dB(A) |
| Nominal cool input | 0.54 kW | 0.89 kW |
| Max pipe / height | 15 m / 8 m | 15 m / 8 m |
Terraces, bedrooms, and the hole panel
A bedroom or study within a short run of the outside wall is the natural home. Fifteen metres sounds generous until the route goes up a floor, along a landing and down a side return. Measure the pipe, not the floor plan. If you need 18 metres, airHome 400's 20 metre class, or a Mitsubishi with a longer table, is the next page to read.
The micro-holes are a cleaning job. Dust that settles in the panel is the trade for the draught pattern. The filter-cleaning guide applies, with extra attention to that face. A product this quiet on paper becomes ordinary if the panel is choked.
There is no 5 kW Elite on this sheet. A large kitchen needs a different Samsung model or a different brand. Stretching a 3.5 because you like the 16 dB(A) figure is how the unit runs on high all evening and the silent number never appears.
Warranty and the existing WindFree pages
Samsung's installer network and the warranty card are the commercial half. A retail-only indoor unit with a condenser fitted by whoever was free on Saturday is a hard way to own a 16 dB(A) promise. Use a company that commissions Samsung and will come back.
WindFree versus Perfera, and WindFree versus AY, already exist for the family. Elite versus airHome is the small-room sheet fight with current numbers. Keep those for the decision. Use this page to check the pipe and the size before you fall for the decibel.
F-gas, a proper circuit, and a drain remain the install. Elite's charm is the indoor behaviour and the efficiency on a short run. Give it that run and it can be the bedroom unit people hoped WindFree meant.
Frequently asked questions
Is 16 dB(A) the normal fan speed?
It is the silent figure on Samsung's sheet. High is 38 or 40 dB(A) depending on size. You hear silent when the room is near setpoint and the mode allows it.
Can I add a third indoor unit?
This sheet is a pair: one indoor, one outdoor. Multi-split WindFree is a different Samsung proposal. Ask for that catalogue if you need two rooms.
What if my pipes need to drop more than 8 metres?
The published height limit is 8 metres. A taller drop needs another model. Forcing it is a warranty and oil-return problem, not a favour the installer should do.
Does WindFree bring in fresh air?
It recirculates. The holes change how the air enters the room. Outdoor air is a ventilation question, unless you have a unit built for that, such as Ururu Sarara.
Core buying guides
Start with these high-intent guides, then dig into the rest of the library.
Related guides
More homes guides
Sources and further reading
How this guide was prepared
This guide was written by the Local AC Installers Editorial Team. We compare official guidance, legislation and established consumer information, separate general information from project-specific advice, and show publication dates and sources. We do not accept installer accreditation claims at face value.