A fan costs pennies but only moves air over you; it does not lower the room temperature. A 40 W fan costs about 1p an hour at the current price cap, while a 2.5 kW split costs about 7p to 10p an hour at full cooling. Use a fan for mild days and a split when the room itself is too hot to sleep in.

Skin, pennies and humid British afternoons
Air movement increases evaporation from skin, so you feel cooler while the fan is on you. The room air is not colder. In a closed room a fan motor adds a little heat. A ceiling fan or a quiet pedestal can still be the most pleasant object in the house on a 24C evening, and it costs pennies an hour compared with cooling a whole room. A fan does not reduce room temperature. The thermometer stays put, aside from a little heat from the motor. Only a system that rejects heat outdoors will lower the room temperature. Evaporative coolers, which wet a pad and blow air through it, are a different product. They struggle on humid British afternoons, when the air has little room left for moisture. A dry fan and a refrigerant split are the two options most UK homes are actually choosing between. A fan is cheaper to run by a wide margin, because it only turns a motor. It also does less. Use it when moving air is enough.
Air conditioning vs a fan
Figures are from the sources listed below, checked 21 November 2026. Running costs use the Ofgem price cap for October to December 2026 (26.32p per kWh of electricity) divided by the published efficiency.
| Fan (40 W example) | Wall split (2.5 kW) | |
|---|---|---|
| Lowers room temperature | No | Yes |
| Removes humidity | No | Yes, while cooling |
| Cost per hour | About 1p | About 7p (SEER 9.47) to 10p (SEER 6.50) |
| Upfront cost | Tens of pounds | About £1,500 to £3,000 installed |
| Buy it if | Mild heat, short spells | Heatwaves, bedrooms that stay hot at night |
A lower room temperature, a higher setpoint, and the sensor
A split lowers the air temperature and takes some moisture out at the coil. That is why a bedroom can be slept in after a 33C day, and why a fan left on all night in the same room still leaves the mattress warm. The split needs an outdoor unit, a lineset, a drain, a dedicated circuit and an F-gas certified install. GOV.UK publishes certification for companies working on that circuit. A fan needs a socket. Running cost follows. As a 2026 illustration, a fan is a small domestic purchase and a trickle of electricity, while a straightforward installed single split still sits in the high hundreds to low thousands of pounds including VAT before it uses any power. You buy the split for the days the fan cannot change the room. Energy Saving Trust's air-to-air guidance is the plain-English account of that heat-pump behaviour. Reverse-cycle splits also heat. A common pattern is a setpoint around 25C plus a ceiling fan, so the room is genuinely cooler than outdoors and the air movement lets people feel comfortable without demanding 20C. The fan should not blow straight into the split's return or onto its thermostat, or the control will hunt. Many households do use a ceiling fan with a split, and it often allows a higher cooling setpoint. In a heatwave night, run the split with the window shut. In a milder night, the fan alone may be enough and the split can stay off. That choice saves more than arguing about SEER decimals. Filters still matter on the days the split does run. A fan can let you keep a higher setpoint. It cools people, not the room.
Leases, listed facades and a desk fan at work
Spare rooms, short occupancies, and summers you can ride out with night purging and shade may never justify an outdoor unit. Planning constraints, a listed facade or a lease that forbids condensers can make the fan the only available tool. The Planning Portal page on air source heat pumps is the heating-plant starting point, and it will not invent a condenser position the building forbids. Accept that limit instead of buying a portable machine that hoses heat back into the same room through a badly fitted window kit. Workplaces have a further duty. HSE expects reasonable thermal comfort, and a desk fan may be part of that, but it does not set a legal maximum temperature and it does not make a dangerously hot process safe. If the building needs cooling, a fan on the counter is not the design.
If a fan will do: two with published figures
A fan does not lower the room temperature, but it costs about a penny an hour and needs no hose. Both figures are Meaco's own.
Pedestal air circulator
MeacoFan 1056P Pedestal Air Circulator
24 W, from 29 dB, 12 speeds
About 0.6p an hour. Throws air across a room and can be aimed, for living rooms and moving air between rooms.
Check price on AmazonPhoto: Meaco
Tower fan
Meaco Sefte Smart 36 inch Tower Fan
34 W, from 20 dB, 12 speeds
About 0.9p an hour. Tall and narrow, with one of the lowest published noise figures we found, for bedrooms.
Check price on AmazonPhoto: Meaco
Comparing another fan? Look for the wattage and a noise figure at the lowest speed. Many cheap fans publish neither.
Frequently asked questions
Does a fan reduce room temperature?
No. It moves air so people feel cooler. The thermometer stays put, aside from a little heat from the motor. Only a system that rejects heat outdoors will lower the room temperature.
Is a fan cheaper to run than air conditioning?
Yes, by a wide margin, because it only turns a motor. It also does less. Use it when moving air is enough, and use a split when the room itself must be cooler.
Can I use a ceiling fan with a split?
Yes. Many households do, and it often allows a higher cooling setpoint. Keep the fan from blowing directly on the indoor unit's sensor.
When is a fan the whole answer?
Spare rooms, short occupancies, and summers you can ride out with night purging and shade may never justify an outdoor unit. Planning constraints, a listed facade or a lease that forbids condensers can make the fan the only available tool. A portable that hoses heat back into the same room is a poor substitute.
Core buying guides
Start with these high-intent guides, then dig into the rest of the library.
Related guides
More technology guides
Sources and further reading
- Energy Saving Trust: Air-to-air heat pumps
- HSE: temperature in the workplace
- GOV.UK: certification for companies working on equipment containing F-gas
- Planning Portal: air source heat pump planning permission
- Ofgem: energy price cap, 1 October to 31 December 2026
- Daikin Europe: Sensira FTXF-F / RXF-F technical table
- Daikin Europe: Perfera FTXM-A / RXM-A9 technical table
How this guide was prepared
This guide was written by the Local AC Installers Editorial Team. We compare official guidance, legislation and established consumer information, separate general information from project-specific advice, and show publication dates and sources. We do not accept installer accreditation claims at face value.