A steel shipping container heats up fast in sun and loses heat fast in winter, so insulation matters more than the air conditioner. Once insulated, a 20 ft container office usually needs a split of around 2.5 kW to 3.5 kW and a 40 ft one around 3.5 kW to 5 kW. A reverse-cycle split heats as well as cools, mounts to the steel with suitable brackets, and needs a proper electrical supply and condensate route.

Insulate before you cool
Uninsulated steel walls pass heat straight into the space. Spray foam or insulated panels inside, a light-coloured roof and shading on the sunny side make a bigger difference than a larger air conditioner.
Insulation also stops condensation forming on the inside of the steel in winter, which is a common problem in container offices.
Sizing
Container sizes are standard, so sizing is easier than in a house, but people, computers, glazing and sun exposure still change the answer.
| Container | Typical use | Typical split size |
|---|---|---|
| 10 ft | Small studio or kiosk | 2.0 kW to 2.5 kW |
| 20 ft | Office for one to three people | 2.5 kW to 3.5 kW |
| 40 ft | Larger office or meeting room | 3.5 kW to 5.0 kW |
| Uninsulated or heavily glazed | Any | Insulate first; sizing will be unreliable |
Mounting and pipework
The indoor unit fixes to an internal lining or a timber backing board, not straight to corrugated steel. The outdoor unit can go on ground feet beside the container or on brackets bolted through the steel with sealed fixings.
Pipe and cable holes through the steel need grommets and sealing to stop water and rust. Plan the condensate drain to a gully or soakaway rather than onto the ground beside the door.
Power, planning and use
A container on a site may run from a temporary supply or a generator; one in a garden usually takes a supply from the house. Either way, the circuit needs proper protection and certification.
A container used as a permanent garden office may itself need planning permission, depending on size and position. Check before adding equipment, then use the system in heat pump mode for efficient winter heating too.
Frequently asked questions
What size air conditioner does a shipping container need?
Once insulated, about 2.5 kW to 3.5 kW for a 20 ft container office and 3.5 kW to 5 kW for a 40 ft one.
Can you fix an air conditioner to a shipping container?
Yes. The indoor unit fixes to a lining or backing board, and the outdoor unit goes on feet or sealed brackets through the steel.
Do shipping containers need insulating for air conditioning?
Yes. Without insulation, steel walls let heat in so quickly that air conditioning struggles and condensation forms in winter.
Can a container air conditioner heat in winter?
Yes, a reverse-cycle split heats efficiently as well as cooling.
Core buying guides
Start with these high-intent guides, then dig into the rest of the library.
Related guides
More commercial guides
- Server Rack Cooling Versus Room Cooling
- Shop and Retail Air Conditioning: Designing for Customers, Staff and Stock
- Restaurant and Cafe Cooling: Managing Heat Without Compromising Ventilation
- Air Conditioning for Showroom Lighting Heat in the UK
- Removing a commercial air conditioner in London
- Air conditioning for a small UK business
Sources and further reading
How this guide was prepared
This guide was written by the Local AC Installers Editorial Team. We compare official guidance, legislation and established consumer information, separate general information from project-specific advice, and show publication dates and sources. We do not accept installer accreditation claims at face value.