The floor-standing Perfera, FVXM, is Daikin's answer when the only solid wall is short, sloped, or already a window. It sits on the floor, about 600 mm high and 750 mm wide, and can throw air along the floor as well as from the top, which is a kinder winter pattern than a high jet of heat. The FVXM-A catalogue lists the smallest at 2.4 kW nominal cooling, SEER 8.55 and SCOP 4.65, with silent cooling at 20 dB(A). A later suffix such as A9 needs its own sheet. The generic floor-console guide is the form. This page is the Perfera floor model.

Rooms that cannot host a high wall unit
Loft bedrooms with the eaves cutting the wall at shoulder height. Conservatory-style extensions where the only masonry is a low pier. A room under a stair. A glazed gable. In those rooms a wall Perfera is a drawing, not an install. FVXM takes the floor zone people already accept for a radiator.
In heating, air from low down warms the occupied part of the room first. A high wall unit in heating can leave ankles cool and the ceiling warm. That is the physics people are buying with a floor console, alongside cooling in July. The wall-versus-floor guide stays with the general choice. FVXM is the Daikin version with a model code.
It is still a split. The outdoor unit, the pipes, the drain and the F-gas company are the same family of work as a wall unit. You have moved the indoor furniture. You have not removed the plant outside.
FVXM-A catalogue figures
These are FVXM-A with RXM-R from Daikin's floor Perfera data. Nominal cooling is 2.4 and 3.4 kW on the two smaller sizes, not the 2.5 and 3.5 people shorthand. A quote that says A9 or another suffix needs the matching sheet. Treat this table as the A-generation baseline, and check before you compare it with a wall Perfera's label.
| 25A | 35A | 50A | |
|---|---|---|---|
| Cooling nominal | 2.4 kW | 3.4 kW | 5.0 kW |
| Heating nominal | 3.4 kW | 4.5 kW | 5.8 kW |
| SEER | 8.55 | 8.11 | 7.30 |
| SCOP | 4.65 | 4.63 | 4.31 |
| Class, cool / heat | A+++ / A++ | A+++ / A++ | A++ / A+ |
| Silent cool / heat | 20 / 19 dB(A) | 20 / 19 dB(A) | 27 / 29 dB(A) |
| Max pipe / height | 20 m / 15 m | 20 m / 15 m | 30 m / 20 m |
Clearance, curtains and condensate
The unit needs free air at the top outlet and along the floor outlet. Full-length curtains, a sofa pushed tight, or a basket of throws will steal that. Daikin's 600 by 750 by 238 mm carcass, about 17 kg on the smaller sizes, looks compact until the curtain track is in the photo. Take the photo with the curtains closed.
Condensate is the classic floor-console snag, because you are often on an outside wall at skirting level and sometimes below the drain outside. Gravity is a gift. A pump is a named extra with a service life. The floor-standing and condensate guides cover the plumbing patterns. Here, the point is to see the route on day one.
Heating operation on the A-generation outdoor data is about -15 to 18 deg C. Fine for UK shoulder seasons and many winter days. If this unit is the only heat in a loft that sees colder snaps, ask for the output at a low outdoor temperature, not only the SCOP.
When the wall unit was the right Perfera after all
If a clear wall exists above head height, a wall Perfera is usually the simpler, often higher-labelled choice, and it keeps the floor for furniture. FVXM is the specialist, not the upgrade. People sometimes pay for floor standing because it sounds premium. It is premium when the architecture demands it.
Sound at 20 dB(A) silent on the small sizes is bedroom-credible, close to the wall units people sleep with. The 50A steps up to 27 dB(A). A big floor unit in a small loft will be the thing you hear. Size it for the gain, then look at the sound row.
Ask the installer to write FVXM and the suffix, the nominal cooling they are using (2.4, not a rounded 2.5, on the 25A), and the curtain clearance. Then the quote is comparable with a wall-unit alternative on the one wall that might work. You will see the truth quickly.
Frequently asked questions
Is the floor Perfera a 2.5 kW unit?
FVXM25A is published at 2.4 kW nominal cooling. Use 2.4 when you compare it with wall units sold as 2.5.
Can it go in a loft with a sloping ceiling?
That is a classic reason to choose it, provided the upright low wall can take the 600 mm height and the outlets stay clear of the eaves and the curtains.
Does a newer A9 model use this table?
Use the datasheet for the suffix on the quote. This table is the FVXM-A generation. A newer code can move SEER, sound and dimensions.
Will it heat better than a wall unit?
It delivers heat lower in the room, which often feels better at the sofa. The SCOP on the 25A is 4.65, A++ heating. A wall Perfera may post a higher SCOP. Comfort at ankle height and the label are both allowed to matter.
Core buying guides
Start with these high-intent guides, then dig into the rest of the library.
Related guides
More homes guides
Sources and further reading
How this guide was prepared
This guide was written by the Local AC Installers Editorial Team. We compare official guidance, legislation and established consumer information, separate general information from project-specific advice, and show publication dates and sources. We do not accept installer accreditation claims at face value.