On most Daikin wall units with an ARC remote, point the remote at the indoor unit and hold the Cancel button for about five seconds until "00" flashes. Press Cancel repeatedly: the unit gives a short beep for each code and one long beep when the display shows the stored fault. Some models show the code in the Onecta app or on a wired controller instead.
Daikin fault code list
| Code | Meaning and usual causes | What to do |
|---|---|---|
| A1 | Indoor unit circuit board fault Power surge, moisture or a failed indoor PCB | Book an engineer |
| A3 | Drain level problem Blocked condensate drain, failed drain pump or float switch | Book an engineer |
| A5 | Freeze-up protection or high-pressure control Blocked filters, low airflow, dirty coil or a faulty heat exchanger sensor | Try safe checks first |
| A6 | Indoor fan motor fault Seized or failed fan motor, loose connector or PCB fault | Book an engineer |
| C4 | Indoor heat exchanger temperature sensor fault Failed or disconnected thermistor | Book an engineer |
| C9 | Room (suction air) temperature sensor fault Failed or disconnected thermistor | Book an engineer |
| E1 | Outdoor unit circuit board fault Failed outdoor PCB, power disturbance | Book an engineer |
| E3 | High-pressure protection activated Blocked outdoor coil or airflow, outdoor fan fault, overcharge | Try safe checks first |
| E5 | Compressor overload Low refrigerant, blocked airflow, valve or compressor fault | Book an engineer |
| E6 | Compressor lock Compressor failed to start: electrical or mechanical compressor fault | Switch off and call an engineer |
| E7 | Outdoor fan motor lock Obstruction in the fan, failed fan motor or PCB | Try safe checks first |
| F3 | Discharge pipe temperature too high Low refrigerant from a leak, blocked circuit or sensor fault | Book an engineer |
| H6 | Compressor position sensor fault Compressor wiring, inverter board or compressor fault | Book an engineer |
| H9 | Outdoor air temperature sensor fault Failed or disconnected thermistor | Book an engineer |
| J3 | Discharge pipe temperature sensor fault Failed or disconnected thermistor | Book an engineer |
| J6 | Outdoor heat exchanger temperature sensor fault Failed or disconnected thermistor | Book an engineer |
| L4 | Inverter heat sink temperature too high Blocked outdoor airflow, fan fault or inverter board fault | Try safe checks first |
| L5 | Inverter output overcurrent Compressor or inverter board fault | Switch off and call an engineer |
| U0 | Refrigerant shortage A refrigerant leak, or a closed service valve after installation | Book an engineer |
| U2 | Supply voltage problem Low or unstable mains voltage, wiring or inverter fault | Book an engineer |
| U4 | Communication error between indoor and outdoor units Interconnecting cable fault, power interruption or PCB fault | Try safe checks first |
| UA | Indoor and outdoor unit mismatch Incompatible units connected or wrong settings after installation | Book an engineer |
What the three actions mean
- Try safe checks first Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
- Book an engineer This needs testing with instruments. Note the code, model and when it started, then book an F-gas qualified engineer. Do not keep resetting the unit.
- Switch off and call an engineer Switch the system off at the isolator and leave it off. Running it can damage the compressor. Book an F-gas qualified engineer.
What to tell the engineer
- The exact code and when it first appeared.
- The model number from the indoor unit label, and roughly when it was installed.
- Whether it happens in cooling, heating or both.
- Who installed it and whether it is under warranty.
More Daikin help
- Daikin air conditioning review
- Daikin air conditioning servicing
- Air conditioning repair: faults, callout costs and engineers
- Why is my air conditioning not cooling?
- Air conditioning regas cost
- What voids an air conditioning warranty
Other brands
- Mitsubishi Electric fault codes
- Panasonic fault codes
- LG fault codes
- Samsung fault codes
- Fujitsu fault codes
- Mitsubishi Heavy Industries fault codes
- Haier fault codes
- Gree fault codes
- Search all fault codes
Frequently asked questions
How do I read a Daikin fault code?
On most Daikin wall units with an ARC remote, point the remote at the indoor unit and hold the Cancel button for about five seconds until "00" flashes. Press Cancel repeatedly: the unit gives a short beep for each code and one long beep when the display shows the stored fault. Some models show the code in the Onecta app or on a wired controller instead.
What does Daikin U4 mean?
U4 is a communication error between the indoor and outdoor units. Usual causes: interconnecting cable fault, power interruption or pcb fault. Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
What does Daikin U0 mean?
U0 means refrigerant shortage. A sealed system does not use up refrigerant, so this points to a leak that an F-gas qualified engineer must find and repair before recharging.
Can I reset a Daikin air conditioner to clear a code?
Switch the unit off, turn it off at the isolator for five minutes and restart it once. If the code returns, stop resetting it and book an engineer. Repeated resets can damage the compressor.
Why is my Daikin code not on this list?
Only codes confirmed by manufacturer documentation are listed, and meanings vary by model. These codes apply to Daikin split and multi-split systems. Sky Air and VRV systems share many of them but have longer lists. Check the manual for your unit or give the code and model number to an engineer.