Gree split units show the code on the indoor unit display, often in place of the temperature. H1 is a status message during defrost rather than a fault.
Gree fault code list
| Code | Meaning and usual causes | What to do |
|---|---|---|
| E1 | High pressure protection Dirty coils, a restriction in the circuit or overcharge | Try safe checks first |
| E3 | Low pressure protection Dirty filters or coils, or low refrigerant from a leak | Book an engineer |
| E5 | Overcurrent protection High or unstable supply voltage | Book an engineer |
| E6 | Communication error between indoor and outdoor units Wrong, spliced or damaged interconnecting cable, or a board fault | Try safe checks first |
| E7 | Mode conflict Indoor units on a shared outdoor unit set to different modes | Try safe checks first |
| F1 | Indoor room temperature sensor fault Failed or disconnected sensor | Book an engineer |
| F2 | Indoor evaporator temperature sensor fault Failed or disconnected sensor | Book an engineer |
| F3 | Outdoor air temperature sensor fault Failed or disconnected sensor | Book an engineer |
| F4 | Outdoor pipe temperature sensor fault Failed or disconnected sensor | Book an engineer |
| F5 | Discharge temperature sensor fault Failed or disconnected sensor | Book an engineer |
| H1 | Defrosting (not a fault) Heating mode is clearing ice from the outdoor unit | Try safe checks first |
| H5 | Inverter power module (IPM) protection Supply voltage or compressor drive fault | Switch off and call an engineer |
| C5 | Jumper cap fault Missing jumper, often after a control board was replaced | Book an engineer |
| U3 | DC bus voltage drop Unstable or low mains supply | Book an engineer |
| L9 | Power protection A power surge or supply fault | Book an engineer |
What the three actions mean
- Try safe checks first Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
- Book an engineer This needs testing with instruments. Note the code, model and when it started, then book an F-gas qualified engineer. Do not keep resetting the unit.
- Switch off and call an engineer Switch the system off at the isolator and leave it off. Running it can damage the compressor. Book an F-gas qualified engineer.
What to tell the engineer
- The exact code and when it first appeared.
- The model number from the indoor unit label, and roughly when it was installed.
- Whether it happens in cooling, heating or both.
- Who installed it and whether it is under warranty.
More Gree help
- Gree air conditioning review
- Air conditioning repair: faults, callout costs and engineers
- Why is my air conditioning not cooling?
- Air conditioning regas cost
- What voids an air conditioning warranty
Other brands
- Daikin fault codes
- Mitsubishi Electric fault codes
- Panasonic fault codes
- LG fault codes
- Samsung fault codes
- Fujitsu fault codes
- Mitsubishi Heavy Industries fault codes
- Haier fault codes
- Search all fault codes
Frequently asked questions
How do I read a Gree fault code?
Gree split units show the code on the indoor unit display, often in place of the temperature. H1 is a status message during defrost rather than a fault.
What does Gree E6 mean?
E6 is a communication error between the indoor and outdoor units. Usual causes: wrong, spliced or damaged interconnecting cable, or a board fault. Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
Can I reset a Gree air conditioner to clear a code?
Switch the unit off, turn it off at the isolator for five minutes and restart it once. If the code returns, stop resetting it and book an engineer. Repeated resets can damage the compressor.
Why is my Gree code not on this list?
Only codes confirmed by manufacturer documentation are listed, and meanings vary by model. These are the codes Gree lists in its own mini-split guide. Other codes exist on some models; Gree says to check the technical manual for the specific model. Check the manual for your unit or give the code and model number to an engineer.