LG units show the code as "CH" followed by two digits on the indoor unit display or wired controller. Some models show a two-character code such as E1 or F4 for the same faults. The ThinQ app can also show the code.
LG fault code list
| Code | Meaning and usual causes | What to do |
|---|---|---|
| CH01 | Indoor temperature sensor fault Sensor open or short circuit | Book an engineer |
| CH02 | Indoor inlet pipe sensor fault Sensor open or short circuit | Book an engineer |
| CH05 | Communication error between indoor and outdoor units (E0 on some models) Interconnecting cable fault, power interruption or PCB fault | Try safe checks first |
| CH10 | Indoor fan fault (E6 on some models) Obstructed or failed indoor fan motor | Book an engineer |
| CH38 | Low refrigerant (F4 on some models) A refrigerant leak | Book an engineer |
| CH61 | Overheating of the outdoor unit in cooling, or the indoor unit in heating Dirty filters, blocked airflow around the outdoor unit, dirty coil | Try safe checks first |
| CH04 | Drainage problem (shown as FL on some models) Blocked condensate drain or drain pump fault | Try safe checks first |
| CH07 | Operating mode conflict between indoor units One indoor unit is set to heat while another is set to cool or dry on a shared outdoor unit | Try safe checks first |
| CH34 | Same as CH61: overheating protection Blocked airflow around the outdoor unit in cooling, or dirty filters in heating | Try safe checks first |
| CH53 | Communication error between indoor and outdoor units Interconnecting cable fault, power interruption or PCB fault | Try safe checks first |
| CH54 | Reverse phase detected on the power supply Supply wiring fault, often after electrical work | Book an engineer |
| CH66 | Communication cable or pipe connection problem between the units Wiring or piping fault, usually after installation or relocation | Book an engineer |
| CH67 | Outdoor fan fault (shown as EF on some models) Debris, snow or ice blocking the outdoor fan, or a failed fan motor | Try safe checks first |
| CH90 | Protection stop during the test run Piping connection or refrigerant problem found at commissioning | Book an engineer |
| CH91 | Protection stop during the test run Piping connection or refrigerant problem found at commissioning | Book an engineer |
| CH93 | Communication error between indoor and outdoor units Power or interconnecting cable fault; on models from 2021 both units need power | Try safe checks first |
What the three actions mean
- Try safe checks first Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
- Book an engineer This needs testing with instruments. Note the code, model and when it started, then book an F-gas qualified engineer. Do not keep resetting the unit.
- Switch off and call an engineer Switch the system off at the isolator and leave it off. Running it can damage the compressor. Book an F-gas qualified engineer.
What to tell the engineer
- The exact code and when it first appeared.
- The model number from the indoor unit label, and roughly when it was installed.
- Whether it happens in cooling, heating or both.
- Who installed it and whether it is under warranty.
More LG help
- LG air conditioning review
- Air conditioning repair: faults, callout costs and engineers
- Why is my air conditioning not cooling?
- Air conditioning regas cost
- What voids an air conditioning warranty
Other brands
- Daikin fault codes
- Mitsubishi Electric fault codes
- Panasonic fault codes
- Samsung fault codes
- Fujitsu fault codes
- Mitsubishi Heavy Industries fault codes
- Haier fault codes
- Gree fault codes
- Search all fault codes
Frequently asked questions
How do I read a LG fault code?
LG units show the code as "CH" followed by two digits on the indoor unit display or wired controller. Some models show a two-character code such as E1 or F4 for the same faults. The ThinQ app can also show the code.
What does LG CH05 mean?
CH05 is a communication error between the indoor and outdoor units. Usual causes: interconnecting cable fault, power interruption or pcb fault. Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
What does LG CH38 mean?
CH38 means low refrigerant (f4 on some models). A sealed system does not use up refrigerant, so this points to a leak that an F-gas qualified engineer must find and repair before recharging.
Can I reset a LG air conditioner to clear a code?
Switch the unit off, turn it off at the isolator for five minutes and restart it once. If the code returns, stop resetting it and book an engineer. Repeated resets can damage the compressor.
Why is my LG code not on this list?
Only codes confirmed by manufacturer documentation are listed, and meanings vary by model. LG publishes help for a limited set of codes, and some models show a short code instead (E0 for CH05, E6 for CH10, EF for CH67, F4 for CH38). Other CH codes exist; confirm those in the manual for your model. Check the manual for your unit or give the code and model number to an engineer.