Fault code lookup

Mitsubishi Heavy Industries air conditioning fault codes

19 Mitsubishi Heavy Industries error codes with their meaning, usual causes and what to do next.

  • 19 codes
  • Checked 21 November 2026

Mitsubishi Heavy Industries (MHI) is a different company from Mitsubishi Electric. On SRK wall units with a wireless remote, a fault shows as a flashing pattern on the indoor unit's RUN and TIMER lamps, and the outdoor board shows a red LED pattern; the service handbook translates each pattern. With a wired remote controller the E code below appears on the screen.

Mitsubishi Heavy Industries fault code list

Mitsubishi Heavy Industries air conditioning fault codes
CodeMeaning and usual causesWhat to do
E3Signal transmission error between indoor and outdoor units
Power supply problem, broken signal wire or indoor or outdoor PCB fault
Try safe checks first
E5Signal transmission error between indoor and outdoor units
Power supply problem, broken signal wire or indoor or outdoor PCB fault
Try safe checks first
E9Drain error
Failed drain pump, broken pump wire or float switch fault
Book an engineer
E16Indoor fan motor fault
Failed fan motor or poor connector connection
Book an engineer
E35High pressure protection in cooling
Overload, overcharge, outdoor coil sensor fault or a closed service valve
Try safe checks first
E36Compressor overheating
Low refrigerant, discharge sensor fault or a closed service valve
Book an engineer
E37Outdoor heat exchanger sensor fault
Broken sensor wire, poor connection or outdoor PCB fault
Book an engineer
E38Outdoor air temperature sensor fault
Broken sensor wire, poor connection or outdoor PCB fault
Book an engineer
E39Discharge pipe sensor fault
Broken sensor wire, poor connection or outdoor PCB fault
Book an engineer
E40Running with the gas-side service valve closed
Service valve left closed after installation, or outdoor PCB fault
Switch off and call an engineer
E42Compressor current cut
Compressor locked, open phase, power transistor short or closed service valve
Switch off and call an engineer
E47Active filter voltage error
Wrong supply voltage or outdoor PCB fault
Book an engineer
E48Outdoor fan motor fault
Obstruction in the fan, failed fan motor or poor connection
Try safe checks first
E51Power transistor fault
Inverter or main PCB fault
Switch off and call an engineer
E53Outdoor suction sensor fault
Broken sensor wire, poor connection or outdoor sub-PCB fault
Book an engineer
E57Refrigerant cycle protection
Low refrigerant from a leak, or a closed service valve
Book an engineer
E58Current safe stop
Overload operation, overcharge or a locked compressor
Book an engineer
E59Outdoor unit fault stop
Broken compressor wire or a blocked compressor
Switch off and call an engineer
E60Compressor rotor lock
Compressor fault, open phase or outdoor PCB fault
Switch off and call an engineer

These are the inverter SRK, SRF and DXK domestic codes from MHI's service support handbook. Some sensor faults on wireless-remote models show only as a lamp pattern, with no E code. Commercial FDC and KX systems use a longer list. Meanings can vary by model, so confirm against the manual for your unit.

What the three actions mean

  • Try safe checks first Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
  • Book an engineer This needs testing with instruments. Note the code, model and when it started, then book an F-gas qualified engineer. Do not keep resetting the unit.
  • Switch off and call an engineer Switch the system off at the isolator and leave it off. Running it can damage the compressor. Book an F-gas qualified engineer.

What to tell the engineer

  • The exact code and when it first appeared.
  • The model number from the indoor unit label, and roughly when it was installed.
  • Whether it happens in cooling, heating or both.
  • Who installed it and whether it is under warranty.

More Mitsubishi Heavy Industries help

Other brands

Frequently asked questions

How do I read a Mitsubishi Heavy Industries fault code?

Mitsubishi Heavy Industries (MHI) is a different company from Mitsubishi Electric. On SRK wall units with a wireless remote, a fault shows as a flashing pattern on the indoor unit's RUN and TIMER lamps, and the outdoor board shows a red LED pattern; the service handbook translates each pattern. With a wired remote controller the E code below appears on the screen.

What does Mitsubishi Heavy Industries E57 mean?

E57 means refrigerant cycle protection. A sealed system does not use up refrigerant, so this points to a leak that an F-gas qualified engineer must find and repair before recharging.

Can I reset a Mitsubishi Heavy Industries air conditioner to clear a code?

Switch the unit off, turn it off at the isolator for five minutes and restart it once. If the code returns, stop resetting it and book an engineer. Repeated resets can damage the compressor.

Why is my Mitsubishi Heavy Industries code not on this list?

Only codes confirmed by manufacturer documentation are listed, and meanings vary by model. These are the inverter SRK, SRF and DXK domestic codes from MHI's service support handbook. Some sensor faults on wireless-remote models show only as a lamp pattern, with no E code. Commercial FDC and KX systems use a longer list. Check the manual for your unit or give the code and model number to an engineer.

Sources

Get a quote

Get Mitsubishi Heavy Industries repair quotes near you

Start with the installation postcode and service. Add optional detail only if you have it.

Free, no obligationSubmit the form at no cost. You decide whether to accept any quote.

Local introductionsWe pass your enquiry to installers covering the postcode. Reply speed and volume both vary.

No lead sellingDetails go only to relevant installers for quote contact. See the privacy notice.

Ask each company for F-Gas registration and insurance. We introduce local installers.

Add more project detail (optional)

You choose whether to accept any quote. Read our installer checks and privacy notice.