Fault code lookup

Haier air conditioning fault codes

31 Haier error codes with their meaning, usual causes and what to do next.

  • 31 codes
  • Checked 21 November 2026
Fault codes

Haier split units show the code on the indoor unit display. Haier says these codes can only be fixed by its after-sales engineers, so switch the unit off and arrange service once a code appears.

Haier fault code list

Haier air conditioning fault codes
CodeMeaning and usual causesWhat to do
E1Indoor room temperature sensor fault
Failed or disconnected sensor
Book an engineer
E2Indoor pipe temperature sensor fault
Failed or disconnected sensor
Book an engineer
E4Indoor circuit board memory (EEPROM) fault
Indoor PCB fault
Book an engineer
E5Indoor anti-frost protection
Blocked filters, low airflow or low refrigerant
Book an engineer
E7Communication fault between indoor and outdoor units
Interconnecting cable fault, power interruption or PCB fault
Book an engineer
E9Indoor unit overload in heating
Blocked airflow, dirty filters or overcharge
Book an engineer
E14Indoor fan motor fault
Obstructed or failed fan motor, or PCB fault
Book an engineer
F1Inverter power module (IPM) protection
Compressor drive or outdoor board fault
Switch off and call an engineer
F2Compressor overcurrent
Compressor, inverter or supply fault
Switch off and call an engineer
F3Communication error between the power module and main board
Outdoor board or internal wiring fault
Book an engineer
F4Compressor discharge temperature protection
Low refrigerant from a leak, blocked circuit or sensor fault
Book an engineer
F6Outdoor air temperature sensor fault
Failed or disconnected sensor
Book an engineer
F7Suction temperature sensor fault
Failed or disconnected sensor
Book an engineer
F8Outdoor DC fan motor fault
Obstruction in the fan or a failed fan motor
Book an engineer
F9Power module reset
Supply disturbance or outdoor board fault
Book an engineer
F11Compressor loss of synchronism
Compressor or inverter fault
Switch off and call an engineer
F12Outdoor circuit board memory (EEPROM) fault
Outdoor PCB fault
Book an engineer
F13Lack of refrigerant
A refrigerant leak
Book an engineer
F144-way valve reversing fault
Reversing valve or coil fault
Book an engineer
F19Supply over or under voltage protection
Unstable mains supply or wiring fault
Book an engineer
F20High pressure protection
Blocked outdoor airflow, fan fault or overcharge
Book an engineer
F21Outdoor coil temperature sensor fault
Failed or disconnected sensor
Book an engineer
F22Outdoor AC overcurrent protection
Supply, compressor or board fault
Switch off and call an engineer
F23Compressor phase overcurrent (U, V or W phase)
Compressor winding or inverter fault
Switch off and call an engineer
F24Current transformer detection fault
Outdoor board current sensing fault
Book an engineer
F25Compressor discharge sensor fault
Failed or disconnected sensor
Book an engineer
F27Compressor current sampling circuit fault
Outdoor board fault
Book an engineer
F28Compressor position detection circuit fault
Outdoor board or compressor fault
Switch off and call an engineer
F35Compressor driver board fault
Inverter driver board failure
Switch off and call an engineer
F43Model matching fault
Incompatible indoor and outdoor units or wrong board
Book an engineer
FERefrigerant leak detection fault (fixed-speed units)
Low refrigerant charge from a leak
Book an engineer

These codes are from Haier's own support pages for split air conditioners. Haier advises switching off and calling service for every code listed. Meanings can vary by model, so confirm against the manual for your unit.

What the three actions mean

  • Try safe checks first Switch the unit off, clean the filters, clear anything blocking the indoor and outdoor units, then switch off at the isolator for five minutes and restart once. If the code returns, book an engineer.
  • Book an engineer This needs testing with instruments. Note the code, model and when it started, then book an F-gas qualified engineer. Do not keep resetting the unit.
  • Switch off and call an engineer Switch the system off at the isolator and leave it off. Running it can damage the compressor. Book an F-gas qualified engineer.

What to tell the engineer

  • The exact code and when it first appeared.
  • The model number from the indoor unit label, and roughly when it was installed.
  • Whether it happens in cooling, heating or both.
  • Who installed it and whether it is under warranty.

More Haier help

Other brands

Frequently asked questions

How do I read a Haier fault code?

Haier split units show the code on the indoor unit display. Haier says these codes can only be fixed by its after-sales engineers, so switch the unit off and arrange service once a code appears.

What does Haier F3 mean?

F3 is a communication error between the indoor and outdoor units. Usual causes: outdoor board or internal wiring fault. This needs testing with instruments. Note the code, model and when it started, then book an F-gas qualified engineer. Do not keep resetting the unit.

What does Haier F13 mean?

F13 means lack of refrigerant. A sealed system does not use up refrigerant, so this points to a leak that an F-gas qualified engineer must find and repair before recharging.

Can I reset a Haier air conditioner to clear a code?

Switch the unit off, turn it off at the isolator for five minutes and restart it once. If the code returns, stop resetting it and book an engineer. Repeated resets can damage the compressor.

Why is my Haier code not on this list?

Only codes confirmed by manufacturer documentation are listed, and meanings vary by model. These codes are from Haier's own support pages for split air conditioners. Haier advises switching off and calling service for every code listed. Check the manual for your unit or give the code and model number to an engineer.

Sources

Get a quote

Get Haier repair quotes near you

Start with the installation postcode and service. Add optional detail only if you have it.

Free, no obligationSubmit the form at no cost. You decide whether to accept any quote.

Local introductionsWe pass your enquiry to installers covering the postcode. Reply speed and volume both vary.

No lead sellingDetails go only to relevant installers for quote contact. See the privacy notice.

Ask each company for F-Gas registration and insurance. We introduce local installers.

Add more project detail (optional)

You choose whether to accept any quote. Read our installer checks and privacy notice.